Before anyone touches the motor, controller, phase cables or the inside of the battery area, the high-voltage system must be switched off, disconnected and proven dead. This page explains what a rider or fundi can do safely, and what a trained technician does in the workshop. Isolating the high-voltage system itself is workshop work.
Safety
- High voltage (HV) means the big battery circuit. UNECE rules, used in the IMI standard, call more than 60 V DC high voltage. Many commuter packs are close to this or above it; for example the Super Soco CPx Pro is listed with a 60 V battery. Check the label on your pack.
- Even a lower-voltage pack can push very large currents. A spanner across two terminals can melt, spark and burn you.
- Capacitors in the controller can stay charged after the key is off. Waiting a few minutes never proves the circuit is dead. Only a test with the right meter, at the points the manufacturer names, proves it.
- If the pack is dented, swollen, wet, hot, hissing or smells, do not isolate it yourself. Follow Handle a damaged battery pack.
- Training in first response does not make you competent to repair HV parts (IMI EV02). Work only within your training.
You need
- The service manual for your exact model, with its isolation steps, test points and the voltage it accepts as "safe".
- Gloves, tools and a voltage tester rated for the pack voltage. A cheap multimeter with worn leads is not enough.
- A way to stop someone switching the bike back on: take the key, tag the bike, keep the removed battery with you.
Steps
Rider or fundi (no tools needed):
- Park on level ground on the centre stand or a stable stand. A falling bike can crush a hand.
- Unplug the charger from the wall first, then from the bike.
- Turn the key or power button off. Put the key in your pocket.
- On a swap-battery bike, remove the battery as the operator shows you and put it on a dry, non-flammable surface away from metal objects. Do not touch the battery contacts.
- If the battery is fixed inside the frame, stop here. Tell the workshop or fleet support line what you have done.
Workshop (trained technician only):
- Tell everyone nearby that HV work is starting and mark off the work area.
- Put on the PPE the manufacturer requires and check the tester on a known source before use.
- Follow the manufacturer's isolation steps in order: this may include a service disconnect, a fuse, a main switch or unplugging the pack connector.
- Wait the time the manual gives, then test at the named points. Confirm the reading is below the manufacturer's limit.
- Test the tester again on a known source, so you know it did not fail during the test.
- Lock or tag the isolation point and keep the key or service plug with you.
- When the job is done, re-energise using the manufacturer's steps and test that the system works before the bike goes back to the rider. Write down what was done.
Check your work
- The key and any removed battery or service plug are with the person doing the work.
- The tester proved the circuit dead at the manufacturer's points, and the tester itself was proven working before and after.
- A written note says who isolated the bike and when.
If it did not fix the problem
- Isolation is a safety step, not a repair. Go back to the problem you were diagnosing, for example Diagnose a motor fault or Diagnose a controller fault.
- If the bike shows an insulation warning, see Insulation or high-voltage warning.
Reference values
| Item | Value | Source |
|---|---|---|
| High-voltage threshold (UNECE definition) | more than 60 V DC or 30 V AC | IMI EV02 |
| Example commuter pack | Super Soco CPx Pro: 60 V | Super Soco CPx Pro specification sheet |